Earthquake protection of colonial bell towers in Colima, Mexico with externally prestressed FRPs

Manakin: DSpace XMLUI Project v2

Mostrar el registro sencillo del ítem

dc.contributor.author Preciado, Adolfo
dc.contributor.author Budelmann, Harald
dc.contributor.author Bartoli, Gianni
dc.coverage.spatial Colima, México es
dc.coverage.temporal 2000-2016 es
dc.date.accessioned 2016-05-27T17:29:53Z
dc.date.available 2017-05-28T10:00:17Z
dc.date.issued 2016-05
dc.identifier.citation Preciado, A., Budelmann, H. and Bartoli, G. (2016). “Earthquake protection of colonial bell towers in Colima, Mexico with externally prestressed FRPs”. International Journal of Architectural Heritage, 10(4), pp. 499-515. es
dc.identifier.issn 1558-3066
dc.identifier.uri http://hdl.handle.net/11117/3564
dc.description A methodology for the seismic vulnerability reduction of old masonry towers with external prestressing is presented. It is applied at the Colonial bell-towers of the Cathedral of Colima, Mexico, characterized for being a high seismic area (M>7.5). The 3D FE models are calibrated with experimental data and assessed through nonlinear static approaches including the seismic demand and an accurate validated masonry model. Based on an extensive parametric study on different configurations of old masonry towers, it is selected an optimal prestressing force and device. The Colonial towers are retrofitted with four prestressing devices of FRPs to convert them into a high energy-dissipative reinforced masonry. The external vertical prestressing is included at key points identified in the seismic vulnerability assessment. This technique is in compliance with the demand for architectural conservation and may be located without drilling and unbounded in order to be fully removable. The seismic performance is enhanced by increasing force, displacement, and internal confinement. It is observed an upgrading of 35% and 20% of displacement capacity. With these results it is corroborated that external vertical prestressing allows a substantial increment of ductility for seismic energy dissipation purposes. es
dc.description.sponsorship ITESO, A.C. es
dc.description.sponsorship Technical University of Braunschweig es
dc.description.sponsorship University of Florence es
dc.language.iso eng es
dc.publisher Taylor & Francis Group es
dc.relation.ispartofseries International Journal of Architectural Heritage;10(4)
dc.rights.uri http://quijote.biblio.iteso.mx/licencias/CC-BY-NC-ND-2.5-MX.pdf es
dc.subject Bell-towers es
dc.subject Retrofitting es
dc.subject Strong Earthquakes es
dc.subject Historical Masonry es
dc.subject Nonlinear Assessments es
dc.subject Unbonded Prestressing es
dc.subject FRP Devices es
dc.subject Energy Dissipation es
dc.title Earthquake protection of colonial bell towers in Colima, Mexico with externally prestressed FRPs es
dc.type info:eu-repo/semantics/article es
rei.revisor International Journal of Architectural Heritage
rei.peerreviewed Yes es
rei.embargo.terms 12 meses es


Archivos en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Buscar en todo


Listar

Mi cuenta